NEW-AIRE FIREPLACES


  Wood & Coal Burning Central Heating Fireplaces 
 

 
"The Ultimate Central  Heating System" 

New-Aire Fireplaces burn either Wood or Coal and are designed to centrally heat a house -- or, in lieu of Central Forced Air Heating, the fireplace can function as a Circulating Room/Area Heater.

The New-Aire Fireplace System utilizes refined principles of thermodynamics which are designed to provide the efficiency of any current generation High Efficiency Forced Air Furnace [Radiant, Conductive or Convective Heat Transfer].

By forcing air movement through a series of baffles in a specially designed Heat Exchanger that surrounds a Heavy-Duty Steel Firebox – and with welded-on airtight New-Aire Fireplace Doors and Outside Combustion Air ducted into the firebox -- the New-Aire Fireplace easily matches the heat output of any High Efficiency Furnace on the market today.

In the Fully-Fired Mode, with 1050 cubic feet of air circulation per minute at Central HVAC Static Pressures, the New-Aire Fireplace System produces in excess of 200,000 BTU. 

New-Aire Fireplaces are available in 3 basic designs:

  1. Standard Models

  2. See-Through Models

  3. Room/Area Circulator Models


The Dimensions & Weight of Standard New-Aire Fireplaces are as follows:

                                                        Model 42          Model 44         Model 48

  1. “A” Firebox Opening                           33”                   38”                   42”

  2. “B” Width of Unit                                38”                   42.5”                46.5”

  3. “C” Width of Unit with Motors            70”                   75”                   80”

  4. “D” Height of Unit                               48”                   48”                   48”

  5. Width of Concrete Base                       84”                   88”                   92”

  6. Weight of Unit                                      525 lbs             625 lbs             725 lbs

Click-Here for a schematic and motion depiction of how the New Aire Fireplace provides Central Heating


New-Aire Standard Fireplace Features

  1. Two [2] 525 CFM Two-Speed Blowers.

  2. Grille Brick Frames & Motor Boots.

  3. 10” x 14” Return Air Grilles.

  4. 4” x 30” Adjustable Heated Air Discharge Grille.

  5. Wall Thermostat.  2 Speed Switch with Wall Plate.

  6. Temperature Controlled Blower Switch.

  7. Built-In Log Grates

  8. Clean-Out Door in bottom of firebox

  9. Ash Dump

  10. High Temperature Wiring.

  11. Dual Heat Duct Outlet Rings.


OPTIONS -- New-Aire Standard Fireplace

No Extra Charge:  Central Heat Duct Outlet Rings on either the Top or Side of the Firebox. 

Extra Charge Options:

  1. Corner Unit [Standard Models 42, 44 & 48]

  2. See-Through Construction – Allows viewing from 2 rooms and outside loading with Insulated Security doors.

  3. Heavy Back Construction.

  4. Air-Lator [Outside Combustion Air Damper Assembly].  Increases fireplace efficiency.  Negates Negative Pressure Back-Drafting.  Minimizes creosote buildup.

  5. Outside Air Hood for Air-Lator Duct.

  6. Rotary Control Damper.

  7. Remote Blower Mounting Kit

  8. Door Assembly welded air-tight to firebox.

  9. Door Frame in Metallic Brown, Metallic Blue or Charcoal.

  10. Door Frame & Grilles in Metallic Brown, Metallic Blue or Charcoal.

  11. Gas Log Lighter & Gas Log Lighter Valve.

  12. Outside Wall Ash Clean-Out Door [8” x 8” or 12” x 12”] 

  13. Angle Iron Kit.

  14. Chimney Hood.

  15. BBQ Grill

  16. Bean Pot Holder


Notes:

1.  Concrete Pad dimensions are based on 4” brick installation.  If any wider material is used, extend your Concrete Pad accordingly.  Depth of the Concrete Pad is determined by the weight of the unit, mass of the chimney and local building code.

2.  If the Blowers are installed in a remote location instead of on the sides of the unit, the width of the Concrete Pad can be reduced accordingly.

For remote blowers, an adapter from rectangle to 6” round is welded on the side of the firebox during manufacture, with a transition adapter provided for use at the far end in going from round back to rectangular where the blower is attached.  There is an additional charge for this modification.  The duct piping does not come with the fireplace, but must be provided by the Buyer.  Rigid Duct Piping is more efficient and quieter than Flexible Ducting which may also be used.

The Air-Lator Outside Combustion Air Damper [option] is installed in lieu of bricks in the brick facing in front of the fireplace.  The damper sits just behind the fireplace door in front of the fireplace opening.  

Note:  In an installation without Fireplace Doors to conceal the Air-Lator, the aesthetics of the damper may be deemed unsightly.  Without Fireplace Doors for concealment, the Air-Lator Damper can be recessed and covered with a grille of your choice for better appearance.

The thickness of the metal components in New-Aire Fireplaces is as follows:

  1. Interior Wall -- Sides & Back of Firebox:  7 gauge [3/16"]. 

  2. Optional Heavy Back Fireplace:  3/8".

  3. Outer Wall of Firebox:  16 gauge

  4. Damper:  7 gauge

  5. Bonnet:  12 gauge

  6. Floor:  7 gauge

  7. Built-In Log Grate:  1/2" x 4" with 3/4" Round End Irons

 


INSTALLATION PLANNING

The first planning requirement is the size of the concrete pad base, with the above dimensions based on 4 inch brick installation on all 4 sides of the fireplace.  The width of the concrete pad from front to back must allow 4-8 inches of brick, cement block or other masonry enclosure [depending on State/Local Code], with the sides and back of the firebox wrapped in 1/2 inch insulation -- plus 1/2 inch of dead air space.  Blanket type insulation is provided with the unit.

NEVER install brick, cement blocks or other masonry tightly against the firebox.  A MINIMUM of 1 inch [1/2" insulation + 1/2" dead air space] is required for expansion.  If the back or sides of the firebox are installed against a wall or other combustible surface, an extra 2 inches of dead air space clearance must be provided in addition to the above requirements of masonry surround and expansion air space.

The Rotary Control Damper is an option -- not standard.  The unit comes with a 3 position manual damper.  With welded-on air-tight fireplace doors that allows the manual damper to be set at the desired opening and the combustion burn-rate controlled by the Outside Air Combustion Damper for best efficiency, the Rotary Control Damper is not needed -- and without proper maintenance and cleaning, the Rotary Control Damper can become gummed-up with creosote build-up which impedes its operation.

New-Aire Fireplaces are All-Fuel Rated and can burn either wood or coal.  To burn coal, a Heavy Duty Firebox is required as an option at additional cost.  New-Aire does not provide the Cast Iron or Stainless Steel Coal Grate/Basket that is needed to burn coal.  

Unlike stoves and inserts, the New-Aire Fireplace can be ducted to provide Whole House Central Heating.  New-Aire Fireplaces are certified to the International Mechanical Code -- and,  when connected to induce heat into Central Heating Ductwork, efficiently heats homes of 5000 square feet.


                                               New-Aire Air Tight Fireplace Doors

 

Your home is the Heart of Your Family Life.  A warm hearth is the gathering place that defines the Spirit of A Home. 

The New-Aire Fireplace -- clad in Brass and Glass – provides both the traditional and functional elements desired in today’s lifestyle.

The Door Series [100, 200, 300, 400, 500, 600] refers to the size of the doors and shape of the glass.  The frame of the doors is the same size for all series -- only the size of the doors & class differ.  The cost is the same for each style/series of door.  For colors other than Standard Black, there is an additional cost for Metallic Brown, Metallic Blue or Charcoal.

New-Aire Air Tight Fireplace Doors turns any fireplace into a More Efficient Furnace by controlling the “Burn Rate” to use up to 2/3 less wood.   

Series 100 Fireplace Doors Series 200 Fireplace Doors
Door Opening:  16” x 27.25” Door Opening:  18.5 “ x 32”
Series 300 Fireplace Doors Series 400 Fireplace Doors  
Door Opening:  18” x 27.25” Door Opening:  18” x 27.25”
Series 500 Fireplace Doors   Series 600 Fireplace Doors
Door Opening:  18.5 “ x 32” Door Opening:  18.5 “ x 32”

 


 

NEW-AIRE FIREPLACE SCHEMATIC


        

DOUBLE-WALL CONSTRUCTION & PRINCIPAL OF OPERATION    

New-Aire Fireplaces are constructed with double-walls on both sides and the back of the Fire Box.  When the heated air between the double walls reaches approximately 90 degrees Fahrenheit, a Thermal-Switch closes turning-on the 2 Squirrel Cage Blowers.  Cooler air near the floor is pulled in through the Grille Louvers that cover the Squirrel Cage Blowers, forcing the circulation air into the double-sided walls of the Fire Box.
 
When the two Air Streams meet, they create a "Hurricane Effect" as shown in the Circulation Pattern of the following schematic.  This "Hurricane Effect" is then directed to the sides and back of the New-Aire unit by a series of Thermo-Baffles, which also collect and transmit heat.  The temperature of the air continues to rise as the air rushes through the specially-designed maze of Hot Thermo-Baffles which are welded to the sides and back of the Fire Box, with the air further heated in the Heat Chamber surrounding the Fire Box Bonnet.
The Heated Air is directed throughout the Duct System, providing Forced-Air Central Heating to all the Heat Outlet Registers in the house.  Heated Air may also be discharged directly into the room in which the fireplace is located via Hot Air Adjustable Louvers in the face of the fireplace itself.
 
The entire system is controlled by a Wall Thermostat, as with other Central Heating Systems. 
A Heat Limit Switch inside the fireplace wall prevents the unit from blowing cold air when the fire dies down and the heat collected by the Thermo-Baffels has dissipated.
 
When used in conjunction with another Central Heating System sharing common ductwork, set the Wall Thermostat of the Other Central Heating System at a lower temperature than that selected for the New-Aire Fireplace.  By doing so, your Other Central Heating System will remain off until the fire in the New-Aire Fireplace has died-down and the heat dissipated in the fireplace.
 

 

"HURRICANE EFFECT" HEAT FLOW


 
 
In the schematic above, the  Red Arrows show the "Hurricane Effect" air flow in the Double-Walled Sides & Back of the Fire Box and then flows into the Heat Ducts to be distributed throughout the house or other structure.
 

 

 How the New-Aire Fireplace Provides Central Heating



When the heated air between the double walls of the Fireplace Fire Box reaches approximately 90 degrees Fahrenheit, a Thermal Switch closes turning-on the 2 Squirrel Cage Blowers on both sides of the fireplace to draw cooler room air into the Side Walls of the fireplace where the air is heated and distributed through the duct system to all the Heat Outlet Registers in the house. 
 
Heated Air may also be discharged directly into the room in which the fireplace is located via Hot Air Adjustable Louvers in the face of the fireplace itself.

 

  distillers, stainless water distiller, water processing, reverse osmosis, water bottling plant, bottling plant, commercial water processing, obstacle collision warning, non-electric, non-electric distiller, water plant, water distillation, Volcano stoves, outdoor stove, cooking stove, APS 2000 stove, APS stove,
camping stove, portable stove, wood stove, coal stove, compact stove, small stove, emergency stove, metal stove, stacking stove, dutch oven, dutch stove, outside stove, hunting stove, fishing stove, cabin stove, country stove, amish stove, builders stove,' tailgate stove, tail gate stove, tale gate stove, talegate stove, football stove, Stainless steel, stainless steal, stainless steel cooker, 41 quart canner, stainless steel pressure cooker, stainless pressure cooker, 10 quart pot, ten quart cooker, 10 qt pressure cooker, all american, chef's design, life saver pressure cooker, conquest, conquest international, cic, conqest, konquest, konqest, intl

Copyright (C) 2008